THE SHORT ANSWER

Cryptosporidium is a chlorine-resistant parasite found in most rivers and lakes, so plants that treat surface water, like the Peace River facility and North Port's Myakkahatchee Creek plant, fall under a federal rule called LT2. LT2 makes those systems sample their source water for Cryptosporidium, sort each plant into a "bin" from 1 to 4 by the average level found, and add treatment if the bin is above 1 (40 CFR 141.701, 141.710, 141.711). Your water report only has to print Cryptosporidium results if monitoring "indicates that Cryptosporidium may be present," and none of the local 2025 reports we checked prints any.

FAQ (quick)

  • What is Cryptosporidium? A protozoan parasite. FDOH says its oocysts "are present in most surface waters (e.g. rivers, streams, and lakes) throughout the U.S., and have shown resistance to chlorine."
  • What does it cause? Per FDOH, "watery diarrhea with abdominal cramps, possibly accompanied by fever, nausea, vomiting, and myalgias."
  • Who has to monitor under LT2? Systems using surface water or groundwater under the direct influence of surface water ("Subpart H systems"). Well-only systems aren't covered.
  • What's a "bin"? A risk category set by the average Cryptosporidium level in the source water. Bin 1 is the lowest and needs no added treatment.
  • Why isn't there a Cryptosporidium row in my report? The report rule asks for a summary only when monitoring shows it may be present. Every report does print a standard line about Cryptosporidium for people with weakened immune systems.

Which local water is surface water

  • North Port, Myakkahatchee Creek plant: the city's 2025 report describes "a combination of conventional surface water treatment (sourced from the Myakkahatchee Creek and Coco Plum Waterway) and advanced reverse osmosis technology (sourced from intermediate aquifer wells)."
  • Peace River facility (Peace River Manasota Regional Water Supply Authority): water from the Peace River is stored "in an off stream surface water reservoir," then treated with "color removal (coagulation and sedimentation) with alum, disinfection with chlorine and chloramines, filtration by rapid rate multi-media filters" (Charlotte County Utilities' 2025 Peace River report). This water reaches Charlotte County, North Port, DeSoto County and Sarasota County.
  • Groundwater systems such as Englewood Water District and CCU's Burnt Store list wells as their source in their 2025 reports. LT2 covers Subpart H systems, which use surface water or "ground water under the direct influence of surface water" (40 CFR 141.2), and neither report describes its wells that way.

For how these plants show their filters are working, see turbidity on your water report; we won't repeat the NTU limits here.

How LT2 works, step by step

  1. Sample the source water. "Filtered systems serving at least 10,000 people must sample their source water for Cryptosporidium, E. coli, and turbidity at least monthly for 24 months" (141.701(a)(1)). Smaller filtered systems start with E. coli screening and sample for Cryptosporidium if E. coli is high.
  2. Do it twice. The rule requires a second round of the same monitoring (141.701(b)). For the largest systems, the first round had to start by October 1, 2006 and the second by April 1, 2015.
  3. Get a bin. The plant's average Cryptosporidium concentration sets the bin (141.710(c)):
BinCryptosporidium bin concentration
Bin 1less than 0.075 oocysts/L
Bin 20.075 to less than 1.0 oocysts/L
Bin 31.0 to less than 3.0 oocysts/L
Bin 43.0 oocysts/L or more
  1. Add treatment if needed. For plants using conventional filtration, Bin 1 needs "no additional treatment," Bin 2 needs 1-log, Bin 3 needs 2-log and Bin 4 needs 2.5-log of additional Cryptosporidium treatment (141.711(a)). "Log" is a factor of ten: the federal surface-water rule itself writes "99.9 percent (3-log)" and "99.99 percent (4-log)" (40 CFR 141.70), so 1-log is 90% and 2-log is 99%.
  2. Or skip monitoring by over-treating. A filtered system doesn't have to monitor if it provides "at least 5.5-log of treatment for Cryptosporidium, equivalent to meeting the treatment requirements of Bin 4" (141.701(d)(1)).

EPA sums up the rule's purpose: it "addresses the health effects associated with Cryptosporidium in surface water used as a drinking water supply" (EPA LT2 rule documents).

What your water report says about Cryptosporidium

  • A required health line, in every report. Each local 2025 report we checked prints the federal statement that people with weakened immune systems "should seek advice about drinking water from their health care providers" and that "EPA/CDC guidelines on appropriate means to lessen the risk of infection by Cryptosporidium and other microbial contaminants are available from the Safe Drinking Water Hotline (800-426-4791)" (40 CFR 141.154(a)). Most local reports print "microbiological" in place of "microbial."
  • Results only if it may be present. "If the system has performed any monitoring for Cryptosporidium which indicates that Cryptosporidium may be present in the source water or the finished water, the report must include: (i) A summary of the results of the monitoring; and (ii) An explanation of the significance of the results" (40 CFR 141.153(e)(1)).
  • What local reports print. The 2025 reports from North Port, Charlotte County (Peace River) and Sarasota County don't print Cryptosporidium monitoring results or a bin. The reports don't say why, so we don't read anything into it. To find out a plant's bin, ask the utility.

FAQ

Can I get Cryptosporidium from tap water? FDOH lists "municipal water supplies" among the risk factors most often identified in studies, along with swimming, camping and contact with young animals. For your utility's water, follow any advisory it issues.

What should I do during a boil water notice? Follow the notice. FDOH's advice when water safety is in doubt is to use "commercially bottled water" or "water that has been previously boiled for at least 1 minute and left to cool." See Charlotte County boil water notices.

Does hand sanitizer work against it? FDOH says "alcohol-based hand sanitizers are not effective against Crypto" and recommends washing with soap and water.

I have a private well. Does LT2 cover me? No. LT2 covers public water systems. FDOH advises: "Do not drink untreated water or use untreated ice from lakes, rivers, springs, ponds, streams, or shallow wells." See is Florida well water safe to drink?.

Is this related to the TOC and disinfection byproduct rows? Indirectly. Surface-water plants balance killing microbes against forming byproducts. See total organic carbon in your water report and North Port disinfection byproducts (TTHMs).

Next step

Have questions about your home's water after reading your report? Schedule an in-home water check, or call 941-294-5767. More: North Port drinking water · Service area: North Port · Service area: Port Charlotte · Peace River Manasota water quality

Sources

Drafted 2026-11-20 (America/New_York). Last fact-checked: 2026-11-20 (America/New_York).

PLANNING A NORTH PORT INSTALLATION?

Turn your questions into a clear scope.

Review the home details, equipment questions and ongoing care to discuss before booking. Address coverage and scheduling are confirmed during your callback.

View the North Port installation guide
This guide is educational. Specific treatment recommendations require appropriate water information and an assessment of your home.

A PRACTICAL NEXT STEP

Whole-home filtration, explained.

Target chlorine taste and odor with filtration at your home's entry point.