THE SHORT ANSWER

North Port’s 2025 Consumer Confidence Report lists total trihalomethanes (TTHM) at the city’s own plants averaging 40.35 ppb (range 0.8–47.4) and purchased Peace River water averaging 36.25 ppb (range 32–38). The EPA maximum contaminant level is 80 ppb as a locational running annual average (40 CFR 141.64). Both North Port rows show Violation N. The city’s CCR is the authoritative local table; third-party sites are secondary. Questions: North Port Utilities 941-240-8000.

Who this covers

Homes on North Port Utilities city water. Confirm the name on your bill. For the broader safety question, see Is North Port tap water safe to drink?. For a full CCR walkthrough, see North Port water quality report. This page stays on disinfection byproducts—especially TTHMs—with North Port’s own 2025 numbers.

What disinfection byproducts are

Utilities add chlorine or chloramines to keep water microbiologically safe. Those disinfectants can react with natural organic matter and form disinfection byproducts (DBPs). The two groups homeowners see most often in CCRs are:

  • TTHM — total trihalomethanes
  • HAA5 — five regulated haloacetic acids

For a Southwest Florida overview that is not North Port–specific, see Disinfection byproducts (TTHMs) in tap water. Use those for vocabulary; use the table below for North Port’s current figures.

North Port 2025 CCR: TTHM and HAA5

Figures from North Port’s 2025 Consumer Confidence Report (monitoring Jan–Dec 2025). NP = city plants; PR = purchased Peace River water.

ParameterNP (city plants)PR (Peace River)MCLViolation
TTHM (ppb)40.35 (0.8–47.4)36.25 (32–38)80N / N
HAA5 (ppb)22.55 (0.9–34.4)28.03 (21–32.3)60N / N
Chlorine & chloramines (ppm)1.89 (0.06–3.1)3.85 (3.67–4.2)MRDL 4.0N / N

Lead (tap, 90th percentile) for NP in July 2025 was 3.3 ppb with 0 sites over the action level—useful context, not a DBP. Hardness is not in this CCR.

Find the report via North Port Utilities.

Why “Level Detected” and “Range” both matter

Under the Stage 2 Disinfectants and Disinfection Byproducts Rule, TTHM (and HAA5) compliance is based on a locational running annual average (LRAA) at each monitoring site—not on every single grab sample (40 CFR 141.64).

For North Port’s 2025 NP TTHM row:

  • 40.35 is the reported Level Detected (compliance-style average in the table)
  • 0.8–47.4 is the Range of results
  • Violation remains N

A neighbor’s single kitchen sample is not the same as the utility’s LRAA. That is why one high reading elsewhere in SWFL can sit beside a compliant average—see how CCU Peace River explains a similar pattern in Port Charlotte water quality report.

CCR vs EWG (third-party)

The Environmental Working Group’s Tap Water Database (2026 data set, data through 2025) lists a 19.3 ppb TTHM figure for North Port Utilities (PWS FL6580651) based on its own aggregation, and says the utility was in compliance with federal health-based standards for the latest quarter EPA assessed (January–March 2026) (EWG Tap Water Database — North Port).

Treat EWG as third-party context, not the official compliance table:

SourceRoleNorth Port TTHM figure cited here
North Port 2025 CCRAuthoritative for current complianceNP 40.35; PR 36.25
EWG Tap Water DatabaseIndependent advocacy/database19.3 ppb (third-party; 2026 data set, data through 2025)
EPA MCLLegal limit (LRAA)80 ppb

EWG also publishes its own health guideline (far below the MCL). That guideline is not a legal standard. Meeting the MCL means the utility’s reported averages comply with federal limits in the CCR—it does not settle every household’s taste preference.

What filters can (and cannot) claim

If you want lower DBPs at a drinking faucet than the city's water, which met the TTHM and HAA5 limits in its 2025 report:

  • NSF/ANSI 53 covers many health-effect contaminant reduction claims; TTHM/VOC reduction must appear on the specific listing
  • NSF/ANSI 58 covers reverse osmosis systems; a 58 mark alone does not automatically equal a TTHM claim—check the listing (NSF standards)

Softeners do not remove TTHMs. For kitchen options in North Port, see RO system installation and North Port drinking water—we will not repeat those service pages here.

Practical next steps for North Port homeowners

  1. Confirm you are on North Port Utilities.
  2. Open the current CCR and find the TTHM/HAA5 rows (NP vs PR).
  3. Compare Level Detected and Range to the MCL 80 / 60 columns and the Violation flag.
  4. Decide whether your goal is understanding compliance, improving taste, or lowering DBPs at one faucet.
  5. If you want point-of-use treatment, match certifications to the claim—not a TDS meter reading alone.

FAQ

What is the TTHM level in North Port water? In the 2025 CCR: 40.35 ppb (range 0.8–47.4) for city plants and 36.25 ppb (32–38) for purchased Peace River water, against an MCL of 80 ppb, Violation N.

Is North Port over the TTHM limit? Not in the 2025 CCR rows summarized here. Both NP and PR TTHM lines show Violation N under the 80 ppb MCL.

Why does EWG show 19.3 ppb? That is EWG’s third-party database figure for the system, not the city’s 2025 CCR table. Prefer the CCR for official compliance numbers; link: EWG FL6580651.

Do TTHMs mean the water is unsafe? The CCR’s compliance columns answer the legal standard. Long-term health questions belong with your clinician and EPA/FDEP materials—this page explains how to read North Port’s numbers.

Will a water softener lower TTHMs? No. Softeners treat hardness. Look to listed carbon or RO claims for byproduct reduction at the tap.

Where else should I read? Disinfection byproducts (TTHMs) in tap water for SWFL vocabulary; North Port water quality report for the full local CCR tour.

Sources

Talk to Pure Harbor Water

Want help matching North Port’s TTHM rows to a kitchen filter claim? Call 941-294-5767, request a callback, or Schedule an in-home water check.

PLANNING A NORTH PORT INSTALLATION?

Turn your questions into a clear scope.

Review the home details, equipment questions and ongoing care to discuss before booking. Address coverage and scheduling are confirmed during your callback.

View the North Port installation guide
This guide is educational. Specific treatment recommendations require appropriate water information and an assessment of your home.

A PRACTICAL NEXT STEP

Drinking water, explained.

Fresh-tasting water for every glass, pot of coffee, and family recipe.