THE SHORT ANSWER

North Port Utilities publishes an annual water quality report, also called a Consumer Confidence Report (CCR). It lists what was detected in the city's drinking water during the previous year and compares each result with the legal limit. The city says its 2025 report "meets and exceeds all federal and state drinking water quality standards." The report is on the North Port Utilities page, and questions go to the utility at 941-240-8000. If you just want to know whether the tap water is safe to drink, start with our North Port drinking water guide. This page shows you how to read the report yourself.

Start here

Where to find it

The City of North Port posts its current Consumer Confidence Report, along with earlier years, on the Utilities Department page. The Water Quality page has two more resources worth bookmarking:

Lead Service Line Inventory: a GIS map and property lookup.

Lead and Copper Sampling Reports: the most recent one listed is August 2024.

Federal rules require community water systems to deliver the report by July 1 each year. It covers data from the previous calendar year (40 CFR 141.152).

Not sure your home is on North Port Utilities? Check the name on your water bill. Some addresses near the city are served by another utility or have a private well. See Who supplies my drinking water? and North Port city water vs. well water.

Step 1: Read the source-water section

The report begins by describing where the water comes from. According to the city (Water Quality, About Us, and the 2025 water quality report), North Port's supply includes:

Surface water from Myakkahatchee Creek and the Coco Plum Waterway, treated at the Myakkahatchee Creek Water Treatment Plant.

Six intermediate-aquifer wells (about 220 ft deep) that feed the same plant's reverse osmosis process.

Treated surface water bought from the Peace River Manasota Regional Water Supply Authority. It's treated at the Peace River plant in DeSoto County.

The Southwest Water Treatment Plant, which treats water from four intermediate-aquifer wells (about 260 ft deep) with reverse osmosis.

Because the city blends several sources, your water's taste can change from time to time. For the Wellen Park side of the city, see Wellen Park water.

Step 2: Learn the five terms in the results table

Every CCR has to define these terms. The definitions below are paraphrased from the federal rule (40 CFR 141.153):

MCL (Maximum Contaminant Level): the highest level of a contaminant allowed in drinking water. This is the legal limit.

MCLG (Maximum Contaminant Level Goal): the level below which there's no known or expected health risk. It's a goal with a margin of safety, not a legal limit, so it's often lower than the MCL.

Action Level (AL): the concentration that, if exceeded, triggers treatment or other steps the system must take. It's used for lead and copper.

MRDL (Maximum Residual Disinfectant Level): the highest level of disinfectant, such as chlorine or chloramine, allowed in drinking water.

Units: ppm (parts per million, mg/L) and ppb (parts per billion, µg/L). A ppm is 1,000 times larger than a ppb, so check the unit column before you compare numbers.

Step 3: Read each row from left to right

For each contaminant, look at four things:

"Violation (Y/N)." This tells you whether the system met the standard.

"Level detected." Compare it with the MCL, not the MCLG.

"Range." One sample can be higher than the reported compliance figure.

"Likely source." For example, erosion of natural deposits or a byproduct of drinking water disinfection.

Two kinds of rows confuse people most often:

Disinfection byproducts (TTHMs and HAA5). These are judged on a locational running annual average (LRAA) at each monitoring site. The EPA limit for TTHMs is 80 ppb (40 CFR 141.64). A high single result in the range column isn't automatically a violation. For more, see Disinfection byproducts (TTHMs) in tap water.

Lead and copper. Here the report gives the 90th percentile of home tap samples, the number of sites above the action level and the range of results (40 CFR 141.153). These samples come from household taps, so plumbing inside a home matters. Use the city's Lead Service Line Inventory lookup for your address, and see Choosing a filter for lead.

What North Port's 2025 report shows

TTHMs averaged 40.35 ppb at the city's own plants and 36.25 ppb for purchased Peace River water (limit 80). HAA5 was 22.55 and 28.03 ppb (limit 60). The disinfectant residual (chlorine/chloramines) averaged 1.89 ppm in the city system and 3.85 ppm for Peace River water (limit 4.0). The 90th percentile for lead was 3.3 ppb (action level 15) and for copper 0.16 ppm (action level 1.3) in July 2025 sampling, with no sites above either action level. Sodium was 88.2 ppm at the Myakkahatchee Creek plant, 48.9 ppm at the Southwest plant and 45.6 ppm for Peace River water. No violations were reported. The report does not list hardness, so measure it at your tap.

Source: North Port 2025 CCR

Step 4: Check what the report doesn't cover

Things that aren't regulated or weren't detected. If a contaminant isn't listed, don't assume the result was zero. Ask the utility what was tested.

Temporary disinfectant changes. The regional supply sometimes switches from chloramines to free chlorine for a few weeks, which can change taste and smell. See Why does North Port water smell like chlorine?.

Your own plumbing. The report describes the water the utility delivers. What comes out of your faucet also depends on your pipes, water heater and any equipment in the home.

The city says it monitors finished water and reports the results to the Department of Health in Sarasota County every month (Water Quality). For a general, non-city-specific walkthrough, see How to read your water quality report.

Step 5: Turn the report into a decision

The report can't tell you which filter to buy, but it helps you ask the right question:

Chlorine or chloramine taste? Look at carbon filtration certified for that claim. See Chlorine or chloramine?.

Want lower TTHMs or dissolved solids at the kitchen tap? Compare models with NSF/ANSI 53 or 58 listings that name the contaminant. See Under-sink reverse osmosis in North Port and How to read a filter certification.

Spots and scale? Measure hardness at your own tap before you choose a softener. See Water softener installation in North Port.

FAQ

Where is the North Port water quality report? On the City of North Port Utilities Department web page, along with earlier years. You can also call North Port Utilities at 941-240-8000.

Is North Port tap water safe to drink? The city says its 2025 report meets and exceeds all federal and state standards. For the full answer, including filters, see North Port drinking water.

What's the difference between MCL and MCLG? The MCL is the legal limit. The MCLG is a health-based goal with a margin of safety, so a level can be above the MCLG and still meet the MCL.

Why is one TTHM result in the range higher than the limit? TTHM compliance is based on a locational running annual average (LRAA) at each monitoring site, not on a single sample. Check the "Violation" column.

Does the report show lead in my house? No. It summarizes samples from selected homes. Use the city's lead service line lookup and, if you're concerned, test your own tap with a certified lab.

Can Pure Harbor read the report with me? Yes. During an in-home water check, we go through your utility's report alongside readings from your own tap.

Sources

City of North Port Utilities Department: 2025 report statement, past reports, 941-240-8000

City of North Port Water Quality: sources, monthly reporting, lead service line inventory, August 2024 lead and copper report

City of North Port Utilities About Us: treatment plants and RO

North Port 2025 Annual Water Quality Report (CCR): sources, 2025 results

40 CFR 141.152: July 1 delivery

40 CFR 141.153: required definitions and lead/copper reporting

40 CFR 141.64: TTHM MCL

Talk to Pure Harbor Water

Got your report but not sure what it means for your home? Call 941-294-5767, request a callback or schedule an in-home water check.

PLANNING A NORTH PORT INSTALLATION?

Turn your questions into a clear scope.

Review the home details, equipment questions and ongoing care to discuss before booking. Address coverage and scheduling are confirmed during your callback.

View the North Port installation guide
This guide is educational. Specific treatment recommendations require appropriate water information and an assessment of your home.

A PRACTICAL NEXT STEP

Drinking water, explained.

Fresh-tasting water for every glass, pot of coffee, and family recipe.

Explore this solution