THE SHORT ANSWER
Most local water reports include a short "Radioactive Contaminants" table with two rows: gross alpha (also called alpha emitters) and combined radium-226 and radium-228. The federal limits are 15 pCi/L for gross alpha and 5 pCi/L for combined radium (40 CFR 141.66), and Florida uses the same numbers. In the 2025 reports from North Port, Charlotte County Utilities, Englewood, Sarasota County and Arcadia, every radioactive row shows no violation. The reports list the likely source as erosion of natural deposits.
FAQ (quick)
- What is a pCi/L? Picocuries per liter. EPA's report language calls it "a measure of radioactivity," and Englewood's report says "measure of the radioactivity in water."
- Why does the report show a goal (MCLG) of zero? The local reports print 0 as the health goal for radium and alpha emitters, next to the enforceable limits (MCLs) of 5 and 15. The limit, not the goal, is what a utility must meet.
- Is any local utility over the limit? No. All the rows below show "N" or "No" for violation.
- Why are some sample dates from 2020–2023? Radioactive rows are tested every few years, not monthly, so reports print the most recent result.
- Can a home system reduce radium? CDC says reverse osmosis systems "may also reduce levels of ... radium," and to check the system's label for the specific claim.
What each row means
| Row in your report | What it measures | Limit (MCL) | Goal (MCLG) as printed in local reports |
|---|---|---|---|
| Gross alpha / alpha emitters (pCi/L) | Total alpha radioactivity, "including radium-226 but excluding radon and uranium" | 15 pCi/L | 0 |
| Combined radium 226 + 228 (pCi/L) | The radium-226 result added to the radium-228 result | 5 pCi/L | 0 |
| Uranium (µg/L), if listed | Uranium by weight | 30 µg/L | Not listed in the local reports we reviewed |
Limits and definitions: 40 CFR 141.66; Florida adopts the same three numbers in Rule 62-550.310.
The health-effects language every utility must use is plain. For alpha emitters: "Some people who drink water containing alpha emitters in excess of the MCL over many years may have an increased risk of getting cancer." For radium: "Some people who drink water containing radium-226 or -228 in excess of the MCL over many years may have an increased risk of getting cancer" (40 CFR 141, Subpart O, Appendix A). The key words are "in excess of the MCL" and "over many years."
Local 2025 reports, side by side
| Utility (2025 report) | Gross alpha (pCi/L) | Combined radium (pCi/L) | Sample date | Violation? |
|---|---|---|---|---|
| North Port Utilities, Peace River Authority water row | 1.6 (range 0.8–2.4) | 1.8 (range 0.8–2.8) | Jan–Dec 2025 | No |
| North Port Utilities, North Port plant row | Not listed | ND (not detected) | Feb 2025 | No |
| Charlotte County Utilities, Peace River report | 2.4 (range 0.8–2.4) | 1.9 (range 0.6–2.2) | Jan–Dec 2025 | No |
| Charlotte County Utilities, Burnt Store | 7.18 | 3.2 | Jun 2020 (alpha), Jun 2023 (radium) | No |
| Englewood Water District | Not listed | 1.1 (flagged "I") | Apr 2021 | No |
| Sarasota County Public Utilities | 2.57 (range ND–2.57) | Listed separately: radium-226 0.90, radium-228 1.90 | 2025 | No |
| City of Arcadia | 12 | 4.54 | Mar 2023 | No |
Sources: North Port Water Quality page (2025 report); CCU Peace River 2025; CCU Burnt Store 2025; EWD 2025; Sarasota County 2025; City of Arcadia 2025.
Notes on reading the table
- "Level detected" isn't always an average. CCU's reports say the radiological number is "the highest average at any of the sampling points or the highest detected level at any sampling point, depending on the sampling frequency." That likely explains why North Port's Peace River row (1.6) and CCU's Peace River row (2.4) differ: both print the same 0.8–2.4 range for Peace River Authority water, and CCU's 2.4 is the top of that range.
- "I" in Englewood's report means "the reported value is between the laboratory method detection limit and the laboratory practical quantitation limit." In plain terms, it was detected at a very low level that the lab can't measure precisely.
- Sarasota County prints radium-226 and radium-228 on separate rows. The federal limit of 5 pCi/L applies to the two combined (40 CFR 141.66(b)). We don't add the two highs together, because they may come from different samples.
- Arcadia is the highest of the group (12 of 15 for alpha, 4.54 of 5 for radium) but still under both limits. More detail on the Arcadia water quality page.
How often utilities test for radioactivity
Florida's rule sets the schedule by how high past results were. If a result is below the lab detection limit, a community system tests that point every nine years. If it's at or below half the limit, every six years. Above half the limit but at or below it, every three years. Over the limit triggers quarterly sampling until four quarters in a row are below it (Rule 62-550.519, in Chapter 62-550). That's why a 2025 report can carry a 2020 or 2021 radioactive result.
Florida also lets a utility use its gross alpha result in place of a separate radium-226 test when gross alpha is 5 pCi/L or less (same rule). So a low gross alpha number can stand in for part of the radium test.
What this means at your tap
- Find the right report. Check the name on your water bill, then open that utility's report. Not sure? See who supplies my drinking water or our local report directory.
- Read the radioactive table. Look at the "Level detected" and "MCL violation" columns, and note the sample date.
- On a private well? These utility numbers don't apply to you. Florida DOH says that "in some counties, testing for naturally occurring radiological contaminants may also be recommended," and to ask your local health department which tests it recommends besides bacteria and nitrate (Florida DOH, Private Wells). See is Florida well water safe to drink? and planning a private well lab sample.
- Want an extra barrier for drinking water? CDC says reverse osmosis systems "may also reduce levels of arsenic, fluoride, radium, sulfate," and more, and to "check the system's label for the specific chemicals it removes" (CDC). See under-sink reverse osmosis, RO installation in North Port and how to read a filter certification.
FAQ
Does Peace River water have radium? Low levels. Both North Port's and Charlotte County Utilities' 2025 reports list combined radium in Peace River Authority water under 2 pCi/L, against a limit of 5. More: Peace River Manasota water quality.
Is radium the same as radon? No. Gross alpha in these reports specifically excludes radon and uranium (40 CFR 141.66(c)).
Where does radium in water come from? Every local report lists "erosion of natural deposits." North Port's report adds "certain minerals that are radioactive and may emit a form of radiation known as alpha radiation."
Does a water softener remove radium? CDC says "some water softeners may also remove ... some radioactive chemicals" and to check the product's label. Don't assume yours does without a listed claim. See water softeners.
Does boiling water remove radium? We didn't find an official source to quote on that, so we don't make the claim. Boiling is for germs during a boil water notice; see Charlotte County boil water notice.
Next step
Want help reading your utility's report or choosing a drinking-water system with the right certification? Schedule an in-home water check, or call 941-294-5767. More: North Port drinking water · How to read your water quality report · Related: Florida's secondary drinking water standards
Sources
Drafted 2026-11-17 (America/New_York). Last fact-checked: 2026-11-17 (America/New_York).
- eCFR, 40 CFR 141.66, Maximum contaminant levels for radionuclides
- eCFR, 40 CFR 141 Subpart O, Appendix A (health-effects language)
- Florida Administrative Code, Chapter 62-550 (Rules 62-550.310 and 62-550.519)
- North Port Utilities, 2025 Annual Report (via Water Quality page)
- Charlotte County Utilities, Peace River 2025 Water Quality Report
- Charlotte County Utilities, Burnt Store 2025 Water Quality Report
- Englewood Water District, 2025 CCR
- Sarasota County Public Utilities, 2025 CCR
- City of Arcadia, 2025 report
- CDC, About Home Water Treatment Systems
- Florida DOH, Private Wells
PLANNING A NORTH PORT INSTALLATION?
Turn your questions into a clear scope.
Review the home details, equipment questions and ongoing care to discuss before booking. Address coverage and scheduling are confirmed during your callback.
View the North Port installation guideA PRACTICAL NEXT STEP
Drinking water, explained.
Fresh-tasting water for every glass, pot of coffee, and family recipe.
Explore this solution