THE SHORT ANSWER
ND means "not detected." North Port's report defines it as indicating "that the substance was not found by laboratory analysis." It doesn't mean the amount is exactly zero. It means the lab's test didn't find it at or above the level that test can detect. A "<" value like "<0.1 (ND)" shows that cutoff. An "I" flag, used in Englewood Water District's report, means "the reported value is between the laboratory method detection limit and the laboratory practical quantitation limit," so it was found, but at a level too low to measure precisely.
FAQ (quick)
- Is ND the same as zero? Not exactly. It means below what the test can detect. For some averages, federal rules count it as zero (see below).
- What does "<0.1" mean? Less than 0.1 in the row's units. North Port pairs these with "(ND)."
- What does "I" mean? Detected, but between the detection limit and the level the lab can reliably quantify.
- What does N/A mean? "Not applicable," as Englewood's report defines it. It's often in the goal (MCLG) column for treatment-technique rows.
- Why isn't every contaminant in the table? Reports must list the regulated contaminants that were detected, and some also print non-detects. Sarasota County also prints a separate list of "other contaminants that were tested for but not detected."
Where these show up in local 2025 reports
| Report (2025) | Example row | What's printed | What it means |
|---|---|---|---|
| North Port Utilities | Asbestos, Peace River water | 0.2 (ND); range <0.2 (ND) | Not detected at the test's 0.2 MFL cutoff |
| North Port Utilities | Fluoride, city plants | <0.1 (ND) | Not detected at 0.1 ppm |
| North Port Utilities | Asbestos, city plants | 1.0; range ND–1.0 | Detected in at least one sample, not in another |
| Englewood Water District | Combined radium | 1.1 I | Found, but below the lab's quantitation limit |
| Sarasota County | Separate list (pesticides, arsenic, antimony and others) | "Tested for but not detected" | Not detected; listed in a note, not the table |
Sources: North Port Utilities (2025 report); Englewood Water District 2025; Sarasota County 2025. More on each row: asbestos in Florida drinking water, fluoride in Florida tap water, radium in Florida tap water.
The three terms behind ND
- Method detection limit (MDL): in plain terms, the lowest level a lab method can tell apart from a blank. Florida's lab rule calls it "an estimate of the minimum amount of a substance that an analytical process can reliably detect." Below it, the result is ND.
- Practical quantitation limit (PQL): Florida defines it as "the lowest level of measurement that can be reliably achieved during routine laboratory operating conditions within specified limits of precision and accuracy." Between the MDL and the PQL, Englewood's report flags the result "I."
- The reported limit: a "<" value tells you the cutoff for that test. Different labs and methods can have different cutoffs, so "ND" in two reports isn't always the same threshold.
The local reports we checked define ND and "I" but don't print the numeric detection limit for each test. If you need it, ask your utility.
Does ND count as zero?
Sometimes, for averaging. For most inorganic contaminants, such as arsenic, fluoride and asbestos, when they're monitored more often than once a year, the federal rule says "any sample below the method detection limit shall be calculated at zero for the purpose of determining the annual average" (40 CFR 141.23(i)(1)). Other contaminant groups have their own averaging rules, so check the rule for the row you're reading.
Reading a range with ND
A range like ND–1.0 means the lowest sample wasn't detected and the highest was 1.0. The "level detected" next to it is what's compared with the limit, and how it's calculated depends on the row. For one example, see chloramine levels in your report.
FAQ
My report says ND for lead. Does my tap have no lead? The report covers the utility's samples. Lead often comes from home plumbing, so a system-wide result doesn't describe every tap. See the 90th-percentile lead number and the North Port lead service line lookup.
I got a home test that says ND. Does it mean the same thing? Only for that test's detection limit. Ask the lab for the limit it used. See water testing in North Port and water testing costs in Sarasota and Charlotte.
Does ND on my report mean I don't need a filter? A filter choice depends on your goals, your plumbing and what's actually at your tap. See how to read your water quality report before buying a filter.
Next step
Want help turning your report into a plan for your home? Schedule an in-home water check, or call 941-294-5767. More: North Port drinking water · RO system installation in North Port · North Port water quality report, explained · Related: Your water report is changing in 2027
Sources
Drafted 2026-11-19 (America/New_York). Last fact-checked: 2026-11-19 (America/New_York).
- North Port Utilities, 2025 Annual Water Quality Report (Utilities Department page)
- Englewood Water District, 2025 CCR
- Sarasota County Public Utilities, 2025 CCR
- Charlotte County Utilities, Peace River 2025 Water Quality Report
- eCFR, 40 CFR 141.23 (inorganic monitoring and compliance)
- Florida Administrative Code, Chapter 62-160 (lab definitions and data qualifier codes)
PLANNING A NORTH PORT INSTALLATION?
Turn your questions into a clear scope.
Review the home details, equipment questions and ongoing care to discuss before booking. Address coverage and scheduling are confirmed during your callback.
View the North Port installation guideA PRACTICAL NEXT STEP
Whole-home filtration, explained.
Target chlorine taste and odor with filtration at your home's entry point.
Explore this solution